Idioma

Upper Treat RZ Rigid Fixation Plate System

Inicio Products ANVISA n°: 80356130215Images for illustrative purposes only The Upper Treat RZ Rigid Fixation Plate System was developed for osteosynthesis of the upper limbs. It is a rigid fixation system made up of titanium plates fixed with screws, providing stabilization and stable fixation of bone fragments, even in cases of osteopenic bones.The KlavFix subsystem plates were developed for the treatment of clavicle fractures and have an anatomical geometry and low profile. They are subdivided into three classes: Anterior Plate, Superior Medial Plate and Superior Distal Plate.This product comes in various types and sizes of plates and screws, which are compatible with each other, so that the surgeon can choose according to the patient’s different anatomical structures. ANVISA n°: 80356130215Images for illustrative purposes only Technical Specifications: UT Blocking and UT Non-Blocking Screws• Made from ASTM F136 titanium alloy• Non-cannulated• Self-tapping• Hexalobular• Identified by color-coding system:• 2.7 mm screws: pink anodized• 3.5 mm screws: blue anodized • KlavFix plates• Made of ASTM F136 titanium alloy and anodized• Anatomical contour and low profile, reducing prominences and minimizing soft tissue irritation• Compatible with all UT and UT non-blocking screw models• Have three orientations (right, left and single), identified by color-coding:• Right: gold anodized• Left: pink anodized• Single: green anodized Models UT Blocking Screws• Proximal and/or distal blocking of the plate, which may or not provide angular stability, depending on how insertion is carried out. • Features:• Distal Thread (Diameter): 2.7 mm• Proximal Thread (Diameter): 5.1 mm• Length: 8 to 24 mm • Distal Thread (Diameter): 3.5 mm• Proximal Thread (Diameter): 5.1 mm• Length: 8 to 24 mm • UT Non-Blocking Screws• Used for compression through the plate’s compression hole in order to facilitate fracture healing or fusion.• Can also be used for neutral fixation through the locking holes. • Features:• Distal Thread (Diameter): 2.7 mm• Head Diameter: 5.0 mm• Length: 8 to 24 mm • Distal Thread (Diameter): 3.5 mm• Head Diameter: 5.0 mm• Length: 8 to 24 mm • KlavFix Plates• Used in conjunction with locking and non-locking screws to reduce and stabilize the fracture or fusion. • KlavFix Superior Distal Plate – KSD• Distal third fractures, including type I fractures (without ligament rupture) and type II fractures (with coracoclavicular rupture); • KlavFix Anterior Lateral Plate – KAL• Extra-articular distal third fractures; • KlavFix Anterior Medial and Superior Medial Plates – KAM and KSM• Middle third fractures in general. MANUAL DOUBT CATÁLOGO VÍDEO Related Products edit post Fastfit Suture Razek edit post EuroScrew edit post FastFit Anchor Razek edit post Cannulated Compression Screw MM Razek

Fast Retriever Cannula

Equipamentos médicos - Razek

Home Products ANVISA No.: 80356139029Images for illustrative purposes only The Fast Retriever Cannula has the function of providing the necessary devices to assist in making sutures in intra-articular or non-articular tissues in orthopedic surgeries in general, in a practical and safe way. ANVISA No.: 80356139029Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models • Straight Loop Hook L (Code: 742740100) • Curved Loop Hook L (Code: 742740200) • Curved Loop Hook C (Code: 742740300) MANUAL CATALOGO DOUBT VÍDEO Related Products edit post Niti Pass edit post Razek Wave Electrode edit post RZ Guide Wire edit post Razek Flush Tip

Fastfit Suture Razek

Home Produtos ANVISA No.: 80356130214Images for illustrative purposes only FastFit Suture Razek is suitable for suturing, approximating and binding soft tissue in orthopaedic surgery. The sutures in the FastFit Suture Razek family are supplied braided and in pre-cut lengths. They are available in thread and loop form. ANVISA No.: 80356130214Images for illustrative purposes only Technical specifications • Produto de uso único • Validade da esterilização: 3 anos Models • FSL 15-90B (Código: 500150020) • FSL 12-90C (Código: 500150030) • FSF 15-90B (Código: 500150040) • FSF 15-90C (Código: 500150050) • FSF 15-90A (Código: 500150060) MANUAL DOUBT CATÁLOGO VÍDEO Related Products edit post Upper Treat RZ Rigid Fixation Plate System edit post EuroScrew edit post FastFit Anchor Razek edit post Cannulated Compression Screw MM Razek

Niti Pass

Home Products ANVISA no.: 80356139027Images for illustrative purposes only Niti Pass is a device designed to allow the manipulation and passage of sutures through bone tunnels in different orthopedic, arthroscopic and open surgical procedures. ANVISA no.: 80356139027Images for illustrative purposes only Specifications: – Single use products– Sterilization shelf life: 3 years Models The Niti Pass is composed of: Braided Nitinol Loop: enables the capture and manipulation of suture threads, allowing them to pass through bone tunnels; External Cannula: flexible cannula that allows the Braided Nitinol Loop to pass through bone tunnels.  Braided nitinol length: 286 mmTube length: 200 mmTube diameter: DE2.5 x DI1.5 mm MANUAL DOUBT CATÁLOGO VÍDEO Related Products edit post Fast Retriever Cannula edit post Razek Wave Electrode edit post RZ Guide Wire edit post Razek Flush Tip

FastFit Anchor Razek

Home Products FastFit Anchor Razek ANVISA No.: 80356130205Images for illustrative purposes only FastFit Anchor Razek The FastFit Anchor Razek flexible suture anchor family is indicated for use in arthroscopic or conventional orthopedic surgical procedures on the upper and lower limbs, in which sutures are used to join soft tissues such as ligaments, tendons or joint capsules to the bone. Its design is based on the principles of minimal aggression and greater holding power. We have needlepoint and non-needlepoint models. Reduced bone removal – the smaller diameter drill makes the hole created for the implant much smaller. As a result, there is greater preservation of the bone-tissue contact surface, as well as less aggression, considerably reducing post-surgical pain;   Complications such as fractures, ostolysis and synovitis, which can occur with other materials, especially bioabsorbable materials, are minimized.   The reduced diameter of the anchor reduces the need for larger bone perforations, which are common with metal, peek and bioabsorbable anchors, minimizing complications such as bone fragility and relesions. In addition, in cases where more anchors are needed, there will be less chance of complications and a greater possibility of their proper positioning;   With the implant based entirely on sutures, the possibility of intra-articular free bodies that can occur in other types of implants is eliminated.   ANVISA No.: 80356130205Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years • Available in three diameters: 1.6 mm, 2.0 mm and 2.5 mm – loaded with very high-strength wires (UHMWPE); Models FASTFIT ANCHOR RAZEK – 1.6 mm  Not adjustable1.6 (FFA 21-16S) – (Code 500120070)1.6 (FFA 21-16M) – (Code 500120075)1.6 (FFA 21-16L) – (Code 500120077)1.6 (FFA 12-16S) – (Code 500120080)1.6 (FFA 12-16M) – (Code 500120085)1.6 (FFA 12-16L) – (Code 500120087) With needles1.6 (FFA 12-16SA) – (Code 500120155)1.6 (FFA 21-16SA) – (Code 500120150)   FASTFIT ANCHOR RAZEK – 2.0 mm Not adjustable2.0 (FFA 22-20M) – (Code 500120060)2.0 (FFA 22-20L) – (Code 500120065) With needles2,0 (FFA 22-20MA) – (Code 500120145)   FASTFIT ANCHOR RAZEK – 2.5 mm Not adjustable2.5 (FFA 22-25M) – (Code 500120090)2.5 (FFA 22-25L) – (Code 500120095) With needles2,5 (FFA 22-25MA) – (Code 500120295)   MANUAL CATALOG VIDEO DOUBT Related Products edit post Cannulated Compression Screw MM Razek edit post FastFit Anchor Razek – Adjustable edit post EuroScrew edit post Razek Snap Off Screw

RZ Guide Wire

Home Products ANVISA No.: 80356130144Images for illustrative purposes only RZ Guide Wire has the function of guiding the cannulated instruments during their insertion through the access portal. ANVISA No.: 80356130144Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models The full list of models is available in the user manual. RZ Guide Wire for Trocar Tip• Diameter: 0.9 mm – 1.6 mm• Length: 100 mm to 300 mm RZ Guide Wire for Double Trocar Tip• Diameter: 0.9 mm – 1.6 mm• Length: 100 mm to 300 mm RZ Guide Wire for Threaded Trocar Tip• Diameter: 2.0 mm – 2.4 mm• Length: 230 mm RZ Guide Wire for Double Threaded Trocar Tip• Diameter: 2.0 mm – 2.4 mm• Length: 230 mm RZ Guide Wire for Diamond Tip• Diameter: 1.6 mm – 2.4 mm• Length: 150 mm to 230 mm RZ Guide Wire for Double Diamond Tip• Diameter: 0.9 mm – 2.4 mm• Length: 100 mm to 230 mm RZ Guide Wire for Threaded Diamond Tip• Diameter: 2.0 mm – 2.4 mm• Length: 230 mm RZ Guide Wire for Double Threaded Diamond Tip• Diameter: 2.0 mm – 2.4 mm• Length: 230 mm RZ Guide Wire for Drill Tip• Diameter: 2.0 mm – 3.5 mm• Length: 200 mm to 500 mm Calibrated RZ Guide Wire• Diameter: 0.8 mm – 2.4 mm• Length: 50 mm to 500 mm RZ Guide Wire for Rigid Diamond Tip• Diameter: 2.0 mm – 3.5 mm• Length: 230 mm to 400 mm RZ Guide Wire for Rigid Drill Tip• Diameter: 2.4 mm – 3.5 mm• Length: 300 mm to 400 mm RZ Guide Wire for Needle Type Drill Tip• Diameter: 2.0 mm – 3.0 mm• Length: 200 mm to 500 mm RZ Guide Wire for Needle Type Diamond Tip• Diameter: 2.0 mm – 3.0 mm• Length: 200 mm to 500 mm RZ Guide Wire for Three-Hole Drill Tip• Diameter: 2.0 mm – 3.0 mm• Length: 200 mm to 500 mm RZ Guide Wire for Three-Hole Diamond Tip• Diameter: 2.0 mm – 3.0 mm• Length: 200 mm to 500 mm RZ Guide Wire for Four-Hole Drill Tip• Diameter: 2.0 mm – 3.0 mm• Length: 200 mm to 500 mm RZ Guide Wire for Four-Hole Diamond Tip• Diameter: 2.0 mm – 3.0 mm• Length: 200 mm to 500 mm MANUAL DOUBT CATALOG VIDEO Related Products edit post Cutters for Foot Surgery edit post RZ Pump Irrigation Device edit post Razek Upper Distraction Hook edit post Stalk Blade Razek

Cannulated Compression Screw MM Razek

Home Products ANVISA No.: 80356130139Images for illustrative purposes only These are screws for bone synthesis made of titanium alloy ASTM F136. They have non-rigid fastening characteristics and a hexalobular fitting. They are cannulated, non-resorbable and self-tapping. They are designed to offer the surgeon the possibility of fast and precise fixation and compression in fractures, fusions and deformity corrections. The MM Razek Cannulated Compression Screw is used in fractures with mini and micro fragments. ANVISA No.: 80356130139Images for illustrative purposes only Technical specifications With Head• Low profile ball head• Compatible with MM Compression Screw Washer• Together with the Washer, it allows for greater distribution of the contact force with the bone surface Double Thread• Headless design, in which the proximal end is tapered and threaded• Total accommodation of the screw, minimizing prominences and tissue irritation• Provides excellent interfragmentary compression during insertion Models Models With Head• Distal Thread Diameter: 2.2 mm• Head Diameter: 3.6 mm• Shank Diameter: 1.8 mm• Thread Length: 4.0 to 15 mm• Size: 10 mm to 40 mm• Washer Diameter: 5.6 mm• Guide Wire: 0.9 x 100 mm Double Thread Models• Distal Thread Diameter: 2.2 mm• Head Diameter: 3.0 mm• Shank Diameter: 1.8 mm• Thread Length: 4.0 to 15 mm• Size: 10 mm to 40 mm• Guide Wire: 0.9 x 100 mm MANUAL CATALOG VIDEO DOUBT Related Products edit post HalluFix PG Razek edit post Razek Snap Off Screw edit post FastFit Anchor Razek edit post PG Razek Cannulated Compression Screw

FastFit Anchor Razek – Adjustable

Home Products ANVISA No.: 80356130205Images for illustrative purposes only FastFit Anchor Razek – Adjustable The FastFit Anchor Razek flexible suture anchor family is indicated for use in arthroscopic or conventional orthopaedic surgical procedures on the upper and lower limbs, in which sutures are used to join soft tissues such as ligaments, tendons or joint capsules to the bone. Its design is based on the principles of minimal aggression and greater holding power.  Reduced bone removal – the smaller diameter drill makes the hole created for the implant much smaller. As a result, there is greater preservation of the bone-tissue contact surface, as well as less aggression, considerably reducing post-surgical pain;   Complications such as fractures, ostolysis and synovitis, which can occur with other materials, especially bioabsorbable materials, are minimized.   The reduced diameter of the anchor reduces the need for larger bone perforations, which are common with metal, peek and bioabsorbable anchors, minimizing complications such as bone fragility and relesions. In addition, in cases where more anchors are needed, there will be less chance of complications and a greater possibility of their proper positioning;   With the implant based entirely on sutures, the possibility of intra-articular free bodies that can occur in other types of implants is eliminated.   ANVISA No.: 80356130205Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years • Available in three diameters: 1.6 mm, 2.0 mm and 2.5 mm – loaded with very high-strength wires (UHMWPE * ForceFiber® Teleflex*); Models FASTFIT ANCHOR RAZEK – 1.6 mm Adjustable1.6 Adjustable (FAA 11-16S) – (Code 500120050)1.6 Adjustable (FAA 11-16M) – (Code: 500120055)1.6 Adjustable (FAA 11-16L) – (Code 500120057)   FASTFIT ANCHOR RAZEK – 2.0 mm Adjustable2.0 Adjustable (FAA 12-20M) – (Code 500120040)2.0 Adjustable (FAA 12-20L) – (Code 500120045)   FASTFIT ANCHOR RAZEK – 2.5 mm Adjustable2.5 Adjustable (FAA 12 25M) – (Code 500120100)2.5 Adjustable (FAA 12 25L) – (Code 500120105) MANUAL CATALOG VIDEO DOUBT Related Products edit post NitFix Razek edit post Cannulated Compression Screw MM Razek edit post Razek Snap Off Screw edit post FastFit Anchor Razek

FastFit Anchor Razek (Model with tape)

Home Products ANVISA No.: 80356130205Images for illustrative purposes only FastFit Anchor Razek (Model with tape) The FastFit Anchor Razek flexible suture anchor family is indicated for use in arthroscopic or conventional orthopaedic surgical procedures on the upper and lower limbs, in which sutures are used to join soft tissues such as ligaments, tendons or joint capsules to the bone. Its design is based on the principles of minimal aggression and greater holding power. ANVISA No.: 80356130205Images for illustrative purposes only More Details Tape models offer a larger contact surface, providing superior clinical results*. The tapes are extremely resistant, made from ultra-high molecular weight polyethylene. *Maia Dias, C., Gonçalves, S.B., Completo, A. et al. Why are tapes better than wires in knotless rotator cuff repairs? An evaluation of force, pressure and contact area in a tendon bone unit mechanical model. J EXP ORTOP 8, 9 (2021). https://doi.org/10.1186/s40634-020-00321-y Technical specifications Single-use product Sterilization validity: 3 years Ø 1.6mm1.6 (FTB 12-16M) – (Code 500120260)1.6 (FTA 12-16M) – (Code 500120265)1.6 (FTB 12-16L) – (Code 500120280)1.6 (FTA 12-16L) – (Code 500120285) Ø 2.5mm2.5 (FTP 22-25M) – (Code 500120270)2.5 (FTP 22-25L) – (Code 500120290) Model with needle2.5 (FTP 22-25MA) – (Code 500120275) Inserting device shank lengthM: 145 mm / L: 255 mmTape Width: 1.5 mm MANUAL CATALOG DOUBT VIDEO Related Products edit post FastFit Anchor Razek (models 1.5 and 1.5 Mini) edit post Fastfit Suture Razek edit post Feet RZ Rigid Fixation Plate System edit post FastFit Razek

FastFit Anchor Razek (models 1.5 and 1.5 Mini)

Home Products ANVISA No.: 80356130205Images for illustrative purposes only Indications for use: Temporomandibular Joint (TMJ), Foot and Ankle, Hand and Wrist FastFit Anchor Razek is a flexible suture anchor that guarantees maximum fixation with minimal bone aggression. The design is minimally invasive and uses highly resistant materials. This guarantees high stability and fewer complications in the post-operative period. The product’s instruments are purchased separately. ANVISA No.: 80356130205Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years • Safe for use in an MRI environment Models • 1.5 Mini (FFM 10-15S) – (Code 500120115)• 1.5 (FFA 11-15S) – (Code 500120125) Adjustable models• 1.5 Mini Adjustable (FAM 10-15S) – (Code 500120110)• 1.5 Adjustable (FAA 10-15S) – (Code – 500120120) Models with needles• 1.5 Mini (FFM 10-15SA) – (Code 500120210)• 1.5 (FFA 11-15SA) – (Code 500120215) MANUAL CATALOG DOUBT VIDEO Related Products edit post PG Razek Cannulated Compression Screw edit post Fastfit Suture Razek edit post FastFit Razek edit post HalluFix PG Razek


Ao aceitar abaixo, estará consentindo que o site possa armazenar Cookies além de concordar com nossa Política de Privacidade. Clique em “Saiba Mais” para se informar sobre o assunto.