Idioma

Disposable Kit for Razek Traction Tower

Products Home Products ANVISA No.: 80356130094Images for illustrative purposes only The Razek Traction Tower Disposable Kit has the function of supplying devices which, used in conjunction with the Razek Traction Tower, distribute the weight of the fingers or arms, enabling the surgeon to position the patient according to the requirements of the wrist or elbow surgical procedures. ANVISA No.: 80356130094Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 2 years Items • Traction Mesh (S, M or L)• Arm Restraint Bracelet• Forearm Restraint Bracelet• Dynamometer Models • Disposable Kit for Razek Traction Tower S (Code 760120100) • Disposable Kit for Razek Traction Tower M (Code 760120200) • Disposable Kit for Razek Traction Tower L (Code 760120300) MANUAL CATALOG DOUBT VIDEO Related Products edit post RZ Pump Irrigation Device edit post MicroFT edit post Razek Upper Distraction Hook edit post Suture Needle

Razek Upper Distraction Hook

Products Home Products ANVISA No.: 80356130048Images for illustrative purposes only Razek Upper Distraction Hook is a device designed to assist in the removal of tissue, according to the requirements of the surgical procedure. ANVISA No.: 80356130048Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models Razek Upper Distraction Hook 20 x 20 x 5 – 2 (Code: 930060000)Including 2 Pieces of 20 x 20 x 5 mm hook with 250 mm cord.   Razek Upper Distraction Hook 20 x 20 x 5 – 4 (Code: 930070000)Including 4 Pieces of 20 x 20 x 5 mm hook with 250 mm cord.   Razek Upper Distraction Hook 30 x 30 x 8 – 2 (Code: 930080000)Including 2 Pieces of 30 x 30 x 8 mm hook with 250 mm cord.   Razek Upper Distraction Hook 30 x 30 x 8 – 4 (Code: 930090000)Including 4 Pieces of 30 x 30 x 8 mm hook with 250 mm cord.   Razek Upper Distraction Hook 40 x 30 x 12 – 2 (Code: 930100000)Including 2 Pieces of 40 x 30 x 12 mm hook with 350 mm cord.   Razek Upper Distraction Hook 40 x 30 x 12 – 4 (Code: 930110000)Including 4 Pieces of 40 x 30 x 12 mm hook with 350 mm cord.   Razek Upper Distraction Hook 50 x 40 x 15 – 2 (Code: 930120000)Including 2 Pieces of 50 x 40 x 15 mm hook with 350 mm cord.   Razek Upper Distraction Hook 50 x 40 x 15 – 4 (Code: 930130000)Including 4 Pieces of 50 x 40 x 15 mm hook with 350 mm cord.   MANUAL DOUBT CATALOG VIDEO Related Products edit post Razek Micro Saw Blades edit post Razek Disposable Tourniquet edit post Foot RZ Traction Mesh edit post Razek Diamond Drills

Cutters for Foot Surgery

Products Home Products ANVISA No.: 80356130085Images for illustrative purposes only Foot Surgery Cutters are used for drilling, cutting and thinning bone in foot surgery. ANVISA No.: 80356130085Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models WEDThe WED models are fine scraping drills designed for moderate and large exostosectomies.• Available lengths:65 mm (active part: 13.2 mm)75 mm (active part: 20 mm)85 mm (active part: 30 mm)• Available fittings: H and F• Available diameters: 2.9 (mm) WEGThe WEG models are fine scraping drills designed for moderate and large exostosectomies.• Available lengths:65 mm (active part: 13 mm)75 mm (active part: 20 mm)80 mm (active part: 30 mm)• Available fittings: H and F• Available diameters: 4.3 (mm) SHAThe SHA models are side-cutting drills designed to perform osteotomies of the smaller toes and eliminate middle exostoses.• Available lengths: 65 mm (active part: 8 mm)• Available fittings: H and F• Available diameters: 2.0 (mm) SHSThe SHS models are side-cutting drills designed to perform osteotomies of the smaller toes and eliminateexostoses.• Available lengths:65 mm (active part: 11.9 mm)• Available fittings: H and F• Available diameters: 2.2 (mm) SHLThe SHL models are side-cutting drills designed to perform thumb osteotomies and eliminate medial exostoses.• Available lengths:65 mm (active part: 13 mm)75 mm (active part: 20 mm)80 mm (active part: 25 mm)85 mm (active part: 30 mm)• Available fittings: H and F• Available diameters: 2.0 x 2.5 x 3.5 (mm) SHNThe SHN models are side-cutting drills designed for performing thumb osteotomies and eliminating medial exostoses.• Available lengths:65 mm (active part: 11 mm)• Available fittings: H and F• Available diameters: 2.2 (mm) BROThe BRO models are thick scraping drills designed to remove large exostoses.• Available lengths: 70 mm (active part: 15.2 mm) / 80 mm (active part: 15.2 mm)• Available fittings: H and F• Available diameters: 3.5 x 4.5 x 5.0 (mm) MANUAL DOUBT CATALOG VIDEO Related Products edit post Foot RZ Traction Mesh edit post TCASys edit post Cannula for Aggressive Bone Lesion edit post Niti Pass

Mini Microdebridement Cannula

Products Home Products ANVISA No.: 80356130060Images for illustrative purposes only The Mini Microdebridement Cannula is used in arthroscopic procedures on small joints (wrist and ankle), in conjunction with the Shaver Handpiece. ANVISA No.: 80356130060Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models They are specified by the type of active tip, type of fittings and internal and external diameters: • Active tip types: MCC – MCCAI – MCCAO – ACC – ACCAI – ACCAO – ACCS – ACCSAI – ACCSAO – MCCS – MCCSAI – MCCSAO – DCM – RB – RBA – OB – OBA – DOA – TB – PA • Fitting types: R – A – F – T – L – E – P – S – K – W – J • Inner/outer diameters 2.2 / 2.8 – 2.5 / 3.5 – 3.5 / 4.5 • Available lengths: 80mm – 115mm • Available Angles: 15°– 30°– 40º The full list of models is available in the user manual. MANUAL DOUBT CATALOG VIDEO Related Products edit post Razek Disposable Tip edit post RZ Guide Wire edit post Cutters for Foot Surgery edit post MicroFT

Cannula for Aggressive Bone Lesion

Products Home Products ANVISA No.: 80356130156Images for illustrative purposes only Used for microdebridement of bone tissue in foot surgery procedures. ANVISA No.: 80356130156Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models They are differentiated by the type of active tip, type of fitting and inner and outer diameters: • Active tip type: ABL (Aggressive Bone Lesion)  • Inner/outer diameters available: 2.0 / 3.5 – 2.4 /4.5 • Available fittings: R – A – F – T – L – E – P – S – K – W – J The full list of models is available in the user manual. MANUAL DOUBT CATALOG VIDEO Related Products edit post MicroFT edit post Razek Dissector Tip edit post Disposable Kit for Razek Traction Tower edit post Razek Blade STC

Razek Disposable Tourniquet

Products Home Products ANVISA No.: 80356130067Images for illustrative purposes only Razek Disposable Tourniquet is used in procedures that need to minimize blood circulation to the limb with a tourniquet during the procedure. The pressure exerted by the tourniquet prevents arterial blood flow to the limb (upper or lower). ANVISA No.: 80356130067Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 2 years Models Razek Disposable Tourniquet S (Code 930280000)Sizes: 40 x 5 cm Razek Disposable Tourniquet M (Code 930290000)Sizes: 50 x 7 cm Razek Disposable Tourniquet L (Code 930300000)Sizes: 80 x 8 cm Razek Disposable Tourniquet XL (Code 930310000)Sizes: 100 x 12 cm MANUAL DOUBT CATALOG VIDEO Related Products edit post Razek Dissector Tip edit post Razek Pump Irrigation Device edit post Suture Compression Hook edit post Razek Wave Electrode

TCASys

Products Home Products TCASys ANVISA No.: 80356130142Images for illustrative purposes only TCASys It enables autologous cartilage transplantation (Mosaicplasty), where osteochondral grafts are taken from a healthy site to be transferred to an area in need of grafting. ANVISA No.: 80356130142Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models TCASys 4 (Code 930320100)It has a Ø 4 mm and should be used on lesions smaller than 10 mm diameter.   TCASys 6 (Code 930320200)It has a Ø 6 mm and should be used on lesions smaller than 10 mm diameter.   TCASys 8 (Code 930320300)It has a Ø 8 mm and should be used on lesions smaller than 10 mm diameter.   TCASys 10 (Code 930320400)It has a Ø 10 mm and should be used on lesions smaller than 10 mm diameter.   MANUAL CATALOG VIDEO DOUBTS Related Products edit post RZ Pump Irrigation Device edit post STP Pain Cannula edit post RZ Guide Wire edit post Suture Compression Hook

Suture Needle

Products Home Produtos Suture Needle ANVISA No.: 80356130170Images for illustrative purposes only Suture Needle Suture Needle is a device designed to allow manipulation of the suture through the tissue in ligament repair or similar surgical procedures, for example: ▪ Repair of the anterior tibiofibular ligament in an ankle arthroscopy procedure using the Inside-Out technique;▪ Treatment of lateral epicondylitis of the elbow in elbow arthroscopy procedures using the Inside-Out technique;▪ Meniscal repair in knee arthroscopy procedures using the Inside-Out technique;▪ Repair of the triangular fibrocartilage complex in wrist arthroscopy procedures using the Inside-Out or Outside-In technique. ANVISA No.: 80356130170Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models ▪ Suture Needle EXL (Code 930370000)2 units of 0.8 mm diameter and 265 mm length  ▪ Suture Needle SXL (Code 930370010)2 units of 0.8 mm diameter and 302 mm length. MANUAL DOUBT CATALOG VIDEO Related Products edit post Puncture Cannula edit post Suture Fix Cannula Kit edit post Compression Hook RZ Pass Niti edit post Razek Blade STC

Razek Pulse Pro

Products Home Products Razek Pulse Pro ANVISA No.: 80356139004Images for illustrative purposes only Razek Pulse Pro Razek Pulse Pro is used to perform rinsing by pulsed pumping of fluids directly into the tip of the product’s cannula concomitantly with suction to conduct waste such as blood, soft tissue, necrotic tissue and fluids also directly into the tip of the cannula. Suction is performed when connected to a hospital aspirator. ANVISA No.: 80356139004Images for illustrative purposes only Technical specifications Technical specifications • Double function: washing and suction  • Acessórios:  Short Cannula (125 mm injector tube) Long Cannula (280 mm injector tube)   • Single-use product   • Sterilization validity: 2 years   Models Razek Pulse Pro (Code 750170000) MANUAL DOUBT CATALOG VIDEO Related Products edit post Compression Hook RZ Pass Niti edit post Puncture Cannula edit post Suture Compression Hook edit post STP Pain Cannula

Razek Suction Tip

Products Home Products ANVISA No.: 80356130210Images for illustrative purposes only Razek Suction Tip has the function of performing tissue ablation, coagulation and cauterization with concomitant suction in monopolar surgical procedures. Razek Suction Tip does not require an electrosurgical pen, as this is part of the product. ANVISA No.: 80356130210Images for illustrative purposes only Technical specifications Single-use product Sterilization validity: 2 years Models • 45° (Code 881520000)• 90° (Code 881520100) MANUAL CATALOG VIDEO DOUBT Related Products edit post Suture Needle edit post TCASys edit post Puncture Cannula edit post Arthrocut Razek