Idioma

Tunneling Tools

Products Home Products ANVISA No.: 80356130177 and 80356130130Images for illustrative purposes only Instruments used to perform drilling in ACL/LCP knee ligament reconstruction surgeries. Tunneling Tool RZ is not part of the product and can be purchased separately. ANVISA No.: 80356130177 and 80356130130Images for illustrative purposes only Items Reducer Guide (Code 930360010) RZ Tunneling Tool Guide (Code 930360020) Knee Guide Body LCA / LCP (Code 930361130) Knee Guide Cannula LCA / LCP – Tunneling Tool (Code 930361140) Guide Tip – Femoral LCA / LCP Outside In – Target (Code 930361150) Guide Tip – Transtibial LCP (Code 930361160) Knee Guide LCA / LCP (Code 930361170) Knee Guide Cannula LCA / LCP – Guide Wire (Code 930361190) Guide Tip – Transtibial LCA Elbow (Code 930361200) Guide Tip – Transtibial LCA Tip (Code 930361210) Guide Tip – Multipurpose (Code 930361250) Guide Tip – Transtibial LCA All-in (Code 930361260) MANUAL CATALOG DOUBT VIDEO Related Products edit post FitPass (R084) edit post Razek Endoscopes for Arthroscopy edit post Razek Irrigation Cannula edit post KneePass (R086)

Razek Irrigation Cannula

Products Home Products ANVISA No.: 80356130127Images for illustrative purposes only The purpose of the Razek Irrigation Cannula is to control and for handling invasive surgical instruments. It also allows liquids to be irrigated and suctioned into cavities. ANVISA No.: 80356130127Images for illustrative purposes only Technical specifications • Diameter: 4.0 mm• Length: 150 mm Model • Razek 150 Irrigation Cannula (Code 700470100) MANUAL DOUBT CATALOG VIDEO Related Products edit post FitPass (R084) edit post Trocar RZ edit post Razek Screw Instruments edit post Hip Arthroscopy Instruments

FastFit Button Razek

Products Home Products FastFit Button Razek ANVISA No.: 80356130203Images for illustrative purposes only FastFit Button Razek Implant for ligament reconstruction, with cortical fixation and adjustable size. Its main applications are in anterior or posterior cruciate ligament (ACL / PCL) injuries, as well as in the reattachment of soft tissue to bone structures. Its unique locking knot allows the graft tension to be adjusted precisely, resisting cyclical displacement and withstanding high tensile loads. Due to its adjustable suture loop, it provides a complete filling of short tunnels, common, for example, in anatomical ACL perforations. Available in 3 versions, SRT for conventional traction via the cortex, STD for tensioning in the direction of the bone tunnel itself and FLF with a fixed loop. The innovative STD system allows the surgeon to advance the graft by pulling the tensioning wires in the same direction as the advance, eliminating the need to retrieve the small cords from the joint and allowing the surgeon to advance in line with the graft. ANVISA No.: 80356130203Images for illustrative purposes only Technical specifications Device with titanium cortical plate and adjustable loop, which maximizes the amount of graft in the tunnel, an ideal solution for accommodating smaller femoral tunnels that result from more anatomical positioning; • EasyFlip typical design that eliminates the need for extra suturing to tilt the device; • Exclusive locking knot that allows precise adjustment of graft tension, as well as resisting cyclical displacement and high tensile loads. • Available in 3 models, with adjustable loop adjustment suture positioned at the top or bottom of the cortical plate and fixed loop model: • Adjustment suture positioned at the bottom of the cortical plate, allows the graft to be tensioned in the direction of the bone tunnel itself.; • Adjustment suture positioned in the upper part of the cortical plate, allowing the graft to be tensioned via the cortex. Composition • Cortical plate made of F136 titanium alloy;• Adjustable suture made of ultra-high molecular weight polyethylene – UHMWPE ** ForceFiber® Teleflex **;• Passage suture made of polyester. Models Adjustable suture loop FastFit Button Razek – SRT (FRT 15 – 00) FastFit Button Razek – STD (FST 15 – 00) Fixed suture loop • FastFit Button Razek – (S15 – FLF 19-15)• FastFit Button Razek – (S20 – FLF 19-20)• FastFit Button Razek – (S25 – FLF 19-25)• FastFit Button Razek – (S30 – FLF 19-30)• FastFit Button Razek – (S35 – FLF 19-35)• FastFit Button Razek – (S40 – FLF 19-40)• FastFit Button Razek – (SS45 – FLF 19-45)• FastFit Button Razek – (S50 – FLF 19-50)• FastFit Button Razek – (S55 – FLF 19-55)• FastFit Button Razek – (S60 – FLF 19-60) MANUAL CATALOG VIDEO DOUBT Related Products edit post FastFit Anchor Razek (Model with tape) edit post FastFit Anchor Razek edit post FastFit Anchor Razek (models 1.5 and 1.5 Mini) edit post FastFit Anchor Razek – Adjustable

Razek Disposable Tourniquet

Products Home Products ANVISA No.: 80356130067Images for illustrative purposes only Razek Disposable Tourniquet is used in procedures that need to minimize blood circulation to the limb with a tourniquet during the procedure. The pressure exerted by the tourniquet prevents arterial blood flow to the limb (upper or lower). ANVISA No.: 80356130067Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 2 years Models Razek Disposable Tourniquet S (Code 930280000)Sizes: 40 x 5 cm Razek Disposable Tourniquet M (Code 930290000)Sizes: 50 x 7 cm Razek Disposable Tourniquet L (Code 930300000)Sizes: 80 x 8 cm Razek Disposable Tourniquet XL (Code 930310000)Sizes: 100 x 12 cm MANUAL DOUBT CATALOG VIDEO Related Products edit post Razek Dissector Tip edit post Razek Pump Irrigation Device edit post Suture Compression Hook edit post Razek Wave Electrode

TCASys

Products Home Products TCASys ANVISA No.: 80356130142Images for illustrative purposes only TCASys It enables autologous cartilage transplantation (Mosaicplasty), where osteochondral grafts are taken from a healthy site to be transferred to an area in need of grafting. ANVISA No.: 80356130142Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models TCASys 4 (Code 930320100)It has a Ø 4 mm and should be used on lesions smaller than 10 mm diameter.   TCASys 6 (Code 930320200)It has a Ø 6 mm and should be used on lesions smaller than 10 mm diameter.   TCASys 8 (Code 930320300)It has a Ø 8 mm and should be used on lesions smaller than 10 mm diameter.   TCASys 10 (Code 930320400)It has a Ø 10 mm and should be used on lesions smaller than 10 mm diameter.   MANUAL CATALOG VIDEO DOUBTS Related Products edit post RZ Pump Irrigation Device edit post STP Pain Cannula edit post RZ Guide Wire edit post Suture Compression Hook

Suture Needle

Products Home Produtos Suture Needle ANVISA No.: 80356130170Images for illustrative purposes only Suture Needle Suture Needle is a device designed to allow manipulation of the suture through the tissue in ligament repair or similar surgical procedures, for example: ▪ Repair of the anterior tibiofibular ligament in an ankle arthroscopy procedure using the Inside-Out technique;▪ Treatment of lateral epicondylitis of the elbow in elbow arthroscopy procedures using the Inside-Out technique;▪ Meniscal repair in knee arthroscopy procedures using the Inside-Out technique;▪ Repair of the triangular fibrocartilage complex in wrist arthroscopy procedures using the Inside-Out or Outside-In technique. ANVISA No.: 80356130170Images for illustrative purposes only Technical specifications • Single-use product • Sterilization validity: 3 years Models ▪ Suture Needle EXL (Code 930370000)2 units of 0.8 mm diameter and 265 mm length  ▪ Suture Needle SXL (Code 930370010)2 units of 0.8 mm diameter and 302 mm length. MANUAL DOUBT CATALOG VIDEO Related Products edit post Puncture Cannula edit post Suture Fix Cannula Kit edit post Compression Hook RZ Pass Niti edit post Razek Blade STC

Razek Pulse Pro

Products Home Products Razek Pulse Pro ANVISA No.: 80356139004Images for illustrative purposes only Razek Pulse Pro Razek Pulse Pro is used to perform rinsing by pulsed pumping of fluids directly into the tip of the product’s cannula concomitantly with suction to conduct waste such as blood, soft tissue, necrotic tissue and fluids also directly into the tip of the cannula. Suction is performed when connected to a hospital aspirator. ANVISA No.: 80356139004Images for illustrative purposes only Technical specifications Technical specifications • Double function: washing and suction  • Acessórios:  Short Cannula (125 mm injector tube) Long Cannula (280 mm injector tube)   • Single-use product   • Sterilization validity: 2 years   Models Razek Pulse Pro (Code 750170000) MANUAL DOUBT CATALOG VIDEO Related Products edit post Compression Hook RZ Pass Niti edit post Puncture Cannula edit post Suture Compression Hook edit post STP Pain Cannula

Razek Suction Tip

Products Home Products ANVISA No.: 80356130210Images for illustrative purposes only Razek Suction Tip has the function of performing tissue ablation, coagulation and cauterization with concomitant suction in monopolar surgical procedures. Razek Suction Tip does not require an electrosurgical pen, as this is part of the product. ANVISA No.: 80356130210Images for illustrative purposes only Technical specifications Single-use product Sterilization validity: 2 years Models • 45° (Code 881520000)• 90° (Code 881520100) MANUAL CATALOG VIDEO DOUBT Related Products edit post Suture Needle edit post TCASys edit post Puncture Cannula edit post Arthrocut Razek

MicroFT

Products Home Products MicroFT ANVISA No.: 80356130129Images for illustrative purposes only MicroFT The purpose of MicroFT is to provides the surgeon with the necessary device to treat chondral/osteochondral cartilage lesions and osteochondritis in different joints. Through chondroplasty and osteochondroplasty, microfracture/microperforation techniques are performed in open surgical treatments or by video arthroscopy, depending on the degree of injury. ANVISA No.: 80356130129Images for illustrative purposes only Technical specifications Single-use product Sterilization validity: 3 years Models MicroFT 0°(Code 742580100)It has a 0° Guide Wire   MicroFT 30°(Code 742580200)It has a 30° Guide Wire   MANUAL CATALOG DOUBT VIDEO Related Products edit post Razek Flush Tip edit post Razek Diamond Drills edit post Razek Wave Electrode edit post RZ Pump Irrigation Device

KneePass (R086)

Products Home Produtos KneePass (R086) ANVISA No.: 80356130034Images for illustrative purposes only KneePass (R086) Razek Arthroscopy Instruments – KneePass (R086) provides a precise passage of the suture in the meniscus repair, with easy capture and retrieval of the thread in a single movement. FitPass suture passer (R086) is safe and easy to use. ANVISA No.: 80356130034Images for illustrative purposes only Technical specifications • 4.5 mm width Suture Passer type tip;• Length: 137 mm. Model KneePass (R086) (Code: 742464400) MANUAL CATALOG VIDEO DOUBT Related Products edit post Meniscus Suturing Instruments edit post Razek Endoscopes for Arthroscopy edit post FitPass (R084) edit post Trocar RZ


Ao aceitar abaixo, estará consentindo que o site possa armazenar Cookies além de concordar com nossa Política de Privacidade. Clique em “Saiba Mais” para se informar sobre o assunto.